General Agriculture

"Empowering farmers with knowledge and utilizing available resources can revolutionize agricultural productivity. From leveraging modern technology to optimizing traditional methods, there's a wealth of strategies at our fingertips. Let's cultivate awareness among farmers, ensuring they harness every tool and technique for a bountiful harvest

Friday, 13 February 2015

Quality Assessment of oil/fat

Quality Assessment of oil/fat
The following methods are used to assess the quality of dietary fats
1) Peroxide Value (Meq/Kg)
2) Free Fatty Acid %
3) Iodine Value (g/100 g)
4) Anisidine Value
5) Color (OD)
6) β- Carotene(ppm)
GC/Head Space Volatile Analysis
The use of volatiles as indicators of lipid oxidation in foods has been well established.
Many analytical methods used for measurement of volatiles generated during lipid oxidation.
GC/MS remains the dominant techniques
Headspace analysis using GC
*      Most biological samples are composed of a wide variety of compounds that differ in molecular weight, polarity, and volatility.
*      A headspace sample is normally prepared in a vial containing the sample, the dilution solvent, a matrix modifier, and the headspace
*      Volatile components from complex sample mixtures can be extracted from non-volatile sample components and isolated in the headspace or vapor portion of a sample vial.
*      An aliquot of the vapor in the headspace is delivered to a GC system for separation of all of the volatile components.
Chemiluminescence (CL)
         The oxidized  sample emits light in pulses
         The intensities of these emissions increases by using photo sensitizer (luminol and lucigenin) which  react with oxidizing species
         oxidation occurs and exited state is attained. On the reverse of exited state emission occurs known as chemiluminescence
         CL Intensity is directly proportion to amount of free radicals or extent of oxidation
Luminometer
*      The photo-oxidized, fried and radiated samples were put in the sample port of Bio-orbit 1250 Luminometery system
*      Light emitted (as a result of chemical reaction between the sample and the sensitizer
*      The CL response recorded as peak  on the chart recorder
Peroxide Value (POV)
Definition: Measure of  amount of oxygen taken up by 1Kg of fat or oil
 Principal : Liberation of free iodine from KI by oxygen present in sample to be titrated against sodium thiosulphate
Reagents
Acetic Acid - Chloroform solution (3:2)
Mix three parts by volume of glacial acetic acid with two parts of chloroform.
Saturated Potassium iodide Solution
Prepare Saturated Potassium iodide (KI) in freshly boiled water
Standard solution of Na2S2O3  (0.01 N)
       Dissolve 2.48g of Na2S2O3 in 1 lit of distilled  water.
      Starch indicator  solution (0.5%)
        Mix 5g of soluble starch in 1000 ml of boiling water
Procedure
*      Take 0.5 - 1 g of oil sample in 250-ml flask
*       Add 25 ml of solvent mixture (glacial acetic acid and chloroform, 3:2)
*      Shake it well to dissolve the oil
*      Add 0.5 ml saturated KI solution  & shake it exactly for 1 min
*      Add 25 ml Distt. water to stop the reaction
*      Add 0.5 ml of starch indicator the blue colour will appear in flask

*      Titrate against 0.01N Na2 S2 O3  till the blue colour disappear& note the reading .

No comments:

Post a Comment

Social Widget

Followers

$(".comments .avatar-image-container img").attr("src", function($this, img) { if (img.match("hqdefault.jpg")) { return img.replace("/hqdefault.jpg", "/mqdefault.jpg"); } else if (img.match("default.jpg")) { return img.replace("/default.jpg", "/mqdefault.jpg"); } else if (img.match("s35-c")) { return img.replace("/s35-c", "/s100-c"); } else if (img.match("s72-c")) { return img.replace("/s72-c", "/s100-c"); } else if (img.match("w72-h72-p-nu")) { return img.replace("/w72-h72-p-nu", "/s100-c"); } else { return img.replace("https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgjzyJyAVRQ9FXNE7VIYjljw-YiiPHF9frUZNF09YZ6Q8tlrVGpXz2NBXif9jmd48k4YFkdig_6KHPYVxrWIK3-_-ehMNV8o7rcuVCRbp-qoapPR38vVKocvslpr_vyzithYWjHw74usm8/s1600-r/nth.png"); } }); //]]>